Chapter 3
76 Concord Express Installation Instructions
Code
System event
699
System Armed Itself (during service or power-
up)
Table 7: System alarm sounds
Code
System event
Fire
Repeating series of three beeps
Police/Intrusion
Continuous tone
Auxiliary
Rapid beeps
Changing Fixed Display LCD Touchpad Chime and
Trouble Beep Tones
The frequency (pitch) of chime and trouble beep tones from a fixed display
touchpad can be adjusted to a more desirable or distinct tone, and to
compensate for hearing impaired persons.
Note: For the comfort of users, chime and trouble beep tones revert to the
quieter, default frequency while the keypad is in use (during or within 15 seconds
of any button activity at that specific touchpad).
To change status tone pitch:
1. Press and hold the * and 0 buttons together until you hear a steady tone, then
release the buttons.
2. Press and hold 1 to lower the pitch or press and hold 2 to raise the pitch.
3. When the desired pitch is heard, release the button.
If there is no touchpad activity for about 15 seconds, the steady tone stops
sounding.
Troubleshooting
This section describes what to do if you experience problems with system
operation. Topics are in alphabetical for easy reference.
Access code
Customer cannot remember access code(s).
1. Check your records to see if you have the customer’s access code(s) on file.
2. Verify the access code(s) using the Downloader.