4.2.65.126 switchport hybrid allowed vlan
Command:
switchport hybrid allowed vlan [all | none | add <vlan_list> | remove <vlan_list> |
except <vlan_list>]
switchport Switching mode characteristics
hybrid Change PVID for hybrid port
allowed Set allowed VLAN characteristics when interface is in hybrid mode
<vlan_list> VLAN IDs of the allowed VLANs when this port is in hybrid mode
add Add VLANs to the current list
all All VLANs
except All VLANs except the following
none No VLANs
remove Remove VLANs from the current list
Default:
All
Usage Guide:
To configure VLAN list of Hybrid VLAN for specific interface
Example:
To configure VLAN list (None) of Hybrid VLAN for GigabitEthernet X/X
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # switchport hybrid allowed vlan none
4.2.65.127 switchport hybrid egress-tag
Command:
switchport hybrid egress-tag [none | all | all except-native]
switchport Switching mode characteristics
hybrid Change PVID for hybrid port
egress-tag Egress VLAN tagging configuration
all Tag all frames
none No egress tagging
except-native Tag all frames except frames classified to native VLAN of the hybrid port
Default:
Untagged Port VLAN