8 IFS MCR300-1T/1S User Manual
Installing the MCR300-1T/1S
Please follow these steps to install the MCR300-1T/1S:
1. Turn off the power of the device/station in a network to
which the MCR300-1T/1S will be attached.
2. Ensure that there is no activity in the network.
3. Connect the fiber cable. Attach the duplex LC connector on
the network cable into the SFP transceiver.
4. Attach fiber cable from the MCR300-1T/1S to the fiber
network. TX, RX must be paired at both ends.
5. Connect a 5 VDC power adapter to the MCR300-1T/1S
and verify that the Power LED powers up.
6. Turn on the power of the device/station; the PWR LEDs
should light when all cables are attached.
Note: It is recommended to use 1000Base-SX / LX SFP
modules available in the IFS Transmission product line. A SFP
transceiver module that is not supported will not be recognized
by MCR300-1T/1S media converter.