Interlogix NS3702-24P-4S Command Line Guide Manuel d'utilisateur Page 269

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 405
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 268
-269-
Usage Guide:
To configure the Event of RMON
Example:
To configure the Event (below table) of RMON
Switch# configure terminal
Switch (config)# rmon event 1 log trap interlogix description error
4.2.169 sfp temperature-threshold
Command:
sfp temperature-threshold <0-100>
sfp temperature-threshold Set a lower high temperature threshold for the secondary
temperature alarm in degrees C.
<0-100> Specifies the new threshold temperature.
Default:
None
Usage Guide:
To configure the SFP temperature-threshold of sFlow
Example:
To configure the SFP temperature-threshold (55 degrees C) of sFlow
Switch# configure terminal
Switch (config)# sfp temperature-threshold 55
4.2.170 snmp-server
Command:
snmp-server
snmp-server Set SNMP server's configurations
Vue de la page 268